AquaVENT® FD140i

AquaVENT FD140i DarkP Armstrong Medical | Medical Device Manufacturer
The AquaVENT® FD140i dual gas flow driver is the only device specifically designed to deliver CPAP and HFOT. Designed for ease of use it delivers safe and effective CPAP and HFOT for Neonatal, Paediatric and Adult Patients.

1 Device, 2 Therapies

Designed with clinicians and patients in mind, the AquaVENT® FD140i dual gas flow driver delivers safe and effective High Flow Oxygen Therapy (HFOT) and Continuous Positive Airway Pressure (CPAP) therapies for Neonatal, Paediatric and Adult patients.

Compared to an invasive ventilator delivering non-invasive therapies, the AquaVENT® FD140i is:

The Perfect Alternative

It is widely recognised that prolonged ventilatory support is associated with poor clinical outcomes and that weaning should be considered as early as possible in the course of mechanical ventilation.

Suitable for adult, neonatal and paediatric patients, AquaVENT® FD140i can become an integral part of your weaning protocol, providing an alternative option to using an invasive ventilator to deliver non-invasive therapies.

Training Site

For more information on using the AquaVENT® FD140i for CPAP or HFOT therapy, please visit our training site.

5 Simple Steps

In only 5 simple steps your patient will be receiving the prescribed level of CPAP or High Flow Oxygen Therapy from AquaVENT® FD140i.

The transition between therapies for escalation, de-escalation or for rest periods is just as straightforward.

Product Codes

Code

Description

Box Quantity

AMFD140I-UK

Gas Flow Driver with Pole Mount and Hoses (complete UK system)

1

AMFD140I-EU

Gas Flow Driver with Pole Mount and Hoses (complete EU system)

1

NeoFlow® Bubble CPAP

The AquaVENT® FD140i Gas Flow driver is specifically designed to deliver Bubble CPAP, with digital control of both flow rate and oxygen concentration. This means ventilators are available for babies requiring invasive ventilation. Benefits from:

Features

NeoFlow® Bubble CPAP circuits contain BioCote® antimicrobial silver additive, protecting it from microbial colonisation.

Resources

Video Material

Play Video
Play Video

Print Material

Product Codes

Code

Description

AMCP1408-005

AquaVENT® Neo Bubble CPAP circuit, with antimicrobial BioCote®, for neonatal patients <10kgs, heated, for use with FPH MR850, GGM 2600A and Wilamed Aircon series heater humidifiers, with a silicone humidification limb length 0.8m, auto-fill humidification chamber, heated inspiratory limb length 1.2m, with 0.3m non-heated incubator limb, non-heated expiratory limb length 1.65m, with water trap, with pressure line ID 3mm length 1.5m, with safety pressure relief valve, with bubble generator jar, with additional incubator limbs and adapter 22mmF/6.5mmM, with nitric oxide measurement port, tubing clips, and circuit change label.

AquaVENT® FD140

The AquaVENT® FD140 is a flow driver for humidified high flow oxygen therapy and CPAP therapy for adults and paediatrics delivered by mask or helmet.

Resources

Video material

Play Video
Play Video

Print material

Face Mask CPAP Mode

The flow provided at the respiratory gas outlet is constant and user-adjustable. The flow range covers the normal range for the CPAP application.

CPAP mode setup navigation Armstrong Medical | Medical Device Manufacturer

Breathing Circuit Setup – CPAP – face mask – heated

CPAP or Paed CPAP with face mask, heated
An active humidifier must be integrated in the heated CPAP breathing circuit. Note To prevent water from the humidifier, which collects during operation, from entering the AquaVENT® FD140, the active humidifier should be placed at a level below that of the AquaVENT® FD140. Note When removing the active humidifier, first disconnect the tube from the AquaVENT® FD140 to prevent water from the humidifier from entering the AquaVENT® FD140.
Assemble the breathing circuit as shown in the following diagram:

FD140 Breathing Circuit Setup HFOT Armstrong Medical | Medical Device Manufacturer

Breathing Circuit Setup – CPAP – face mask – unheated

CPAP or Paed CPAP with face mask, unheated
Connect the breathing circuit as shown in the following diagram:

FD140 Breathing Circuit Setup CPAP or Paed CPAP with face mask unheated Armstrong Medical | Medical Device Manufacturer

Paed CPAP mode

The flow provided at the respiratory gas outlet is constant and user-adjustable. The maximum flow in this mode is 70 l/min.

For Breathing Circuit Setup – please see above under “Breathing Circuit Setup – CPAP – face mask – heated/unheated”

Paed CPAP mode setup navigation Armstrong Medical | Medical Device Manufacturer

Helmet (Hood) CPAP mode

The flow provided at the respiratory gas outlet is constant and user-adjustable. The flow range matches the range required for helmet CPAP. For more information, please refer to chapter 5.5.4 Flow adjustment. The nebuliser is completely deactivated in the helmet CPAP mode.

Helmet CPAP mode setup navigation Armstrong Medical | Medical Device Manufacturer

Breathing Circuit Setup – CPAP – Helmet (Hood)

The AquaVENT® FD140 supports non-invasive ventilation by means of a CPAP helmet. Connect the CPAP helmet to the AquaVent FD140 as shown below:

Note
Observe all instructions provided by the manufacturer
of the accessories.
Warning
Be sure to adjust the required flow according to the
instructions provided by the manufacturer of the CPAP
helmet to avoid accidental CO2 rebreathing.

Note
Depending on their design, CPAP helmets may require
a specific minimum pressure when applied on a
patient.
Warning
When using CPAP helmets with hypercapnic patients,
close monitoring is recommended for adjustment of the
required flow and to avoid CO2 rebreathing.
The approved CPAP helmets are specified in chapter 10.2 Accessories.
Please refer to chapter 1.1 About this manual for details.

HFOT mode setup navigation Armstrong Medical | Medical Device Manufacturer

High Flow Oxygen Therapy (HFOT) mode

The AquaVENT® FD140 is the flow source for high flow oxygen therapy. The flow range is designed for use with nasal canulae from Armstrong. For more information, please refer to chapter 5.5.4 Flow adjustment.

Breathing Circuit Setup – HFOT

The AquaVENT® FD140 can be used as a flow generator for High Flow Oxygen Therapy in the HFOT mode.

The nasal cannula is connected to the breathing circuit in close proximity to the patient. The breathing circuit is basically identical with the illustration in chapter 4.6.

Warning
Be sure to adjust the required flow according to the instructions provided by the manufacturer of the nasal cannula to avoid accidental pressure peaks.